Detecção eletroquímica do fungicida tiabendazol extraído de amostras de suco de uva integral por ponto nuvem com eletrodo de diamante dopado com boro.

dc.contributor.advisor1Andrade, Leonardo Santos
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/5360511377400279
dc.contributor.authorAraujo, Vinicius Evangelista
dc.contributor.refereeAndrade, Leonardo Santos
dc.contributor.refereeOliveira, Gildiberto Mendonça de
dc.contributor.refereeAmorim, Kamila Pereira de
dc.creator.Latteshttps://lattes.cnpq.br/2711608886703416
dc.date.accessioned2025-04-25T16:36:42Z
dc.date.issued2022-10-05
dc.description.abstractO suco de uva integral, no Brasil e no mundo, vem ganhando destaque ao longo dos anos por representar uma excelente opção ao vinho, por sua proveniência e em termos de substâncias com potencial antioxidante, ainda podendo ser consumido de forma mais ampla pela população. O aumento do consumo exige maior capacidade produtiva e, portanto, da melhoria de técnicas de manejo e extensa utilização de intensivos agrícolas, como os agrotóxicos. Uma vez que a ingestão destas substâncias em alimentos prevê diversos tipos de intoxicação, agudas ou crônicas, as técnicas com potencial de determinação e detecção delas surgem como medida de controle de qualidade. Nesse sentido, a metodologia proposta neste trabalho tem como objetivo detectar e determinar o fungicida Tiabendazol (TBZ) em suco de uva integral branco, combinando a Extração por Ponto Nuvem (EPN) com Cromatografia Líquida de Alta Eficiência (CLAE) acoplada à detecção eletroquímica pelo uso de um eletrodo de Diamante Dopado com Boro (DDB). Em vista disso, utilizou-se as técnicas de Voltametria Cíclica e de Pulso Diferencial para caracterização eletroquímica do TBZ e seu comportamento na superfície do eletrodo de trabalho. A partir destas técnicas foi possível selecionar a melhor condição de pH para fase móvel (7,0), respeitando-se os limites de uso da coluna cromatográfica. As melhores condições para extração e pré concentração do TBZ apontaram para uma EPN realizada em pH 6,0, pela adição de 1mL do surfactante Tergitol TMN 6 a 10% (m/m), sem aquecimento (a 27°C) e agitação ultrassônica (20 kHz) por 60 min. O procedimento exibiu um fator de préconcentração (FC) igual a 13. A separação por CLAE foi realizada em colula C8, em fase móvel com Tampão fosfato (pH 7,0):ACN na proporção 69:31 (V/V), fluxo de 1,2 mL/min e detecção eletroquímica com DDB aplicando 1,40 V × Ag/AgCl (3,0 mol/L). O processo foi devidamente validado, apresentando limites de detecção (LD) e de quantificação (LQ) de 14,5 μg/L e 36,2 μg/L, respectivamente. Estes valores são aproximadamente 240 vezes menores do que o que foi encontrado na literatura para determinação de TBZ em suco de uva integral. A recuperação do método foi avaliada entre 98,7% e 116,1% com coeficiente de variação entre 4,8% e 7,4%. A aplicação do método proposto permitiu detectar e determinar TBZ em uma das amostras de suco de uva integral branco comercial analisadas.
dc.description.resumoWhole grape juice, in Brazil and in the world, has been gaining prominence over the years as it represents an excellent option for wine, due to its provenance and in terms of substances with antioxidant potential, even though it can be consumed more widely by the population. The increase in consumption requires greater production capacity and, therefore, the improvement of management techniques and extensive use of intensive agricultural products, such as pesticides. Since the ingestion of these substances in food predicts different types of intoxication, acute or chronic, techniques with the potential to determine and detect them appear as a quality control measure. In this sense, the methodology proposed in this work aims to detect and determine the Thiabendazole (TBZ) fungicide in whole white grape juice, combining Cloud Point Extraction (CPE) with High Performance Liquid Chromatography (HPLC) coupled with electrochemical detection using a Boron-Doped Diamond electrode (DDB). In view of this, Cyclic Voltammetry and Differential Pulse techniques were used for the electrochemical characterization of TBZ and its behavior on the surface of the working electrode. From these techniques it was possible to select the best pH condition for the mobile phase (7.0), respecting the limits of use of the chromatographic column. The best conditions for extraction and pre-concentration of TBZ pointed to a CPE performed at pH 6.0, by adding 1mL of the surfactant Tergitol TMN 6 at 10% (m/m), without heating (at 27°C) and ultrasonic agitation (20 kHz) for 60 min. The procedure showed a pre-concentration factor (FC) of 13. The HPLC separation was performed in C8 column, in mobile phase with Phosphate Buffer (pH 7.0):ACN in the ratio 69:31 (V/V), flow of 1.2 mL/min and electrochemical detection with DDB by applying 1.40 V x Ag/AgCl (3.0 mol/L). The process was duly validated, presenting limits of detection (LOD) and quantification (LOQ) of 14.5 μg/L and 36.2 μg/L, respectively. These values are approximately 240 times lower than what was found in the literature for the determination of TBZ in whole grape juice. Method recovery was evaluated between 98.7% and 116.1% with a coefficient of variation between 4.8% and 7.4%. The application of the proposed method allowed the detection and determination of TBZ in one of the analyzed samples of commercial white whole grape juice.
dc.description.sponsorshipFundação Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
dc.formatPdf
dc.identifier.urihttp://repositorio.ufcat.edu.br/123456789/12021
dc.languagept
dc.publisherUniversidade Federal de Catalão
dc.publisher.countryBrasil
dc.publisher.departmentInstituto de Química (IQ)
dc.publisher.initialsUFCAT
dc.publisher.programPrograma de Pós-Graduação em Química - Mestrado (PPGQ)
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.subjectdetecção eletroquímica
dc.subjecteletrodo de diamante dopado com boro
dc.subjectextração por nuvem
dc.subjectagrotóxicos
dc.subjectsuco de uva integral
dc.titleDetecção eletroquímica do fungicida tiabendazol extraído de amostras de suco de uva integral por ponto nuvem com eletrodo de diamante dopado com boro.
dc.title.alternativeElectrochemical detection of thiabendazole fungicide extracted from whole grape juice samples by cloud point with boron-doped diamond electrode.
dc.typeDissertação

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Dissertação - VINICIUS EVANGELISTA ARAÚJO.pdf
Tamanho:
2.99 MB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: