Extração de contaminantes emergentes por sorção em fase de tecido com determinação por cromatografia líquida de alta eficiência
dc.contributor.advisor1 | Coelho, Luciana Melo | |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/0074807107314789 | |
dc.contributor.author | Campos, Geniara Ribeiro | |
dc.contributor.referee | Coelho, Luciana Melo | |
dc.contributor.referee | Costa, Bruno Elias dos Santos | |
dc.contributor.referee | Freitas, Sílvia de Sousa | |
dc.creator.Lattes | http://lattes.cnpq.br/2453693243837148 | |
dc.date.accessioned | 2025-04-11T11:10:36Z | |
dc.date.issued | 2021-10-08 | |
dc.description.abstract | O presente trabalho descreve o desenvolvimento de uma metodologia analítica de sorção para quantificar os contaminantes emergentes 17α-etinilestradiol (EE2), estrona (E1) e bisfenol-A (BPA) presentes em matrizes aquosas. Para extração dos mesmos, utilizou um tecido 100% algodão que foi modificado estruturalmente obtendo um tecido sol-gel. Esse método analítico é conhecido como Extração por Sorção em Fase de Tecido, do inglês, Fabric Phase Sorptive Extraction (FPSE). O FPSE é uma nova técnica de extração sortiva que integra as vantagens de solventes orgânicos-inorgânicos derivados de sol-gel permeáveis com substratos de tecidos flexíveis e permeáveis, resultando em um meio de extração altamente eficiente, rápido, simples e sensível que pode ser introduzido diretamente em qualquer tipo de matriz fluídica. A detecção e quantificação dos analitos foram realizadas por Cromatografia Líquida de Alta Eficiência (do inglês, HPLC) com detecção UV-vis. As condições cromatográficas determinadas e utilizadas para análise dos processos de otimização foram: coluna cromatográfica (Shimadzu C18 Exsil ODS (4,6 x 250 mm, 5 μm)), fase móvel (MeOH:ACN:H2O (06:38:56 v/v/v)), vazão (1 mL min-1 ), comprimentos de onda (λ= 220 nm), volume de injeção (20 μL) e temperatura (Tam (22-25 o C)). O método desenvolvido foi validado de acordo com os critérios da resolução da ANVISA n° 166, de 24/07/2017 e o guia de validação do INMETRO DOQ-CGCRE-008/2020. Sob condições otimizadas, o método de extração apresentou limites de detecção de 0,003 μg mL-1 (BPA) e 0,015 μg mL-1 (EE2 e E1), limites de quantificação de 0,01 μg mL-1 (BPA) e 0,05 μg mL-1 (EE2 e E1), faixa linear de 0,01 a 10 μg mL-1 para o BPA e 0,05 a 10 μg mL-1 para o EE2 e E1. A precisão intra-dia e inter-dia (DPR%), obteve valores entre 2,08 a 8,53%, atendendo aos critérios estabelecidos pelos órgãos reguladores. A exatidão foi avaliada por meio de testes de recuperação em amostras de água de represa coletadas dentro da cidade de Catalão-GO, apresentando valores na faixa de 80,51-98,24 %. A metodologia proposta foi aplicada satisfatoriamente para determinação dos contaminantes emergentes. | |
dc.description.resumo | The present work describes the development of an analytical sorption methodology to quantify the emerging contaminants 17α-ethinylestradiol (EE2), estrone (E1) and bisphenol-A (BPA) present in aqueous matrices. To extract them, a 100% cotton fabric was used, which was structurally modified, obtaining a sol-gel fabric. This analytical method is known as Fabric Phase Sorptive Extraction (FPSE). FPSE is a new sorptive extraction technique that integrates the advantages of permeable sol-gel derived organic-inorganic solvents with flexible and permeable tissue substrates, resulting in a highly efficient, fast, simple and sensitive extraction medium that can be introduced directly into any type of fluidic matrix. The detection and quantification of analytes were performed by High Performance Liquid Chromatography (HPLC) with UV-vis detection. The chromatographic conditions determined and used to analyze the optimization processes were: column chromatography (Shimadzu C18 Exsil ODS (4.6 x 250 mm, 5 μm)), mobile phase (MeOH:ACN:H2O (06:38:56 v/v/v)), flow (1 mL min-1 ), wavelengths (λ= 220 nm), injection volume (20 μL) and temperature (Tam (22-25 o C)). The developed method was validated according to the criteria of ANVISA resolution no. 166, of 07/24/2017 and the INMETRO DOQ-CGCRE-008/2020 validation guide. Under optimized conditions, the extraction method presented detection limits of 0.003 μg mL-1 (BPA) and 0.015 μg mL-1 (EE2 and E1), quantification limits of 0.01 μg mL-1 (BPA) and 0.05 μg mL-1 (EE2 and E1), linear range from 0.01 to 10 μg mL-1 for BPA and 0.05 to 10 μg mL-1 for EE2 and E1. The intra-day and inter-day precision (DPR%) obtained values between 2.08 and 8.53%, meeting the criteria established by regulatory agencies. The accuracy was evaluated through recovery tests in dam water samples collected within the city of Catalão-GO, presenting values in the range of 80.51- 98.24%. The proposed methodology was satisfactorily applied for determination of emerging contaminants. | |
dc.description.sponsorship | Fundação Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES | |
dc.format | ||
dc.identifier.uri | http://repositorio.ufcat.edu.br/123456789/11971 | |
dc.language | pt | |
dc.publisher | Universidade Federal de Catalão | |
dc.publisher.country | Brasil | |
dc.publisher.department | Instituto de Química (IQ) | |
dc.publisher.initials | UFCAT | |
dc.publisher.program | Programa de Pós-Graduação em Química - Mestrado (PPGQ) | |
dc.rights | http://purl.org/coar/access_right/c_abf2 | |
dc.subject | extração | |
dc.subject | sol-gel | |
dc.subject | estrogênios | |
dc.subject | sorção | |
dc.subject | cromatografia | |
dc.title | Extração de contaminantes emergentes por sorção em fase de tecido com determinação por cromatografia líquida de alta eficiência | |
dc.title.alternative | Extraction of emergimg contaminants by fabric phase sorptive with determination by high performance liquid chromatography | |
dc.type | Dissertação |